EN 407:2020 — Heat & Flame-Related Performance (A–F)

EN 407 uses six indices (A–F) for limited flame spread, contact heat, convective heat, radiant heat, and small/large splashes of molten metal. Levels are 0–4 in many cells, with 0 meaning no performance determined or lowest class per the test setup.

Flame testedEN 407

With flame / burning behavior tested

Pictogram may show flame symbol when relevant indices (e.g. limited flame spread) are evaluated and marked.

No flame testno flame test

No flame test claimed

Other thermal indices may still be present (e.g. contact heat only). Read A–F columns on the declaration.

IndexHazardLevels (summary)What higher levels imply (general)
ALimited flame spread (afterflame / damaged length)0–4Better resistance to ignition and flame propagation on the specimen.
BContact heat0–4Ability to extend time before pain threshold at defined contact temperature.
CConvective heat0–4Insulation against hot gas/convective oven conditions in the test.
DRadiant heat0–4Insulation against radiant heat flux in the test apparatus.
EResistance to small splashes of molten metal0–4More / hotter small droplets required to damage the heat-sensitive PVC film in test.
FResistance to large splashes of molten metal0–4Performance against larger molten metal splash mass in the test.

EN 511:2006 — Protection Against Cold

Cold performance is shown as three values: convective cold, contact cold, and water penetration. Higher convective/contact classes indicate better insulation under the standard’s conditions.

EN 511 pictogramEN 511:2006

The snowflake pictogram accompanies gloves tested to EN 511. The three numbers align to: convective, contact, and water penetration.

ColumnPropertyScaleNotes
1stConvective cold0–4Insulation vs convective cooling on a heated hand form (higher = better insulation).
2ndContact cold0–4Resistance to heat transfer when gripping a cold cylinder (higher = better).
3rdWater penetration0 or 10 = water penetration after 5 min; 1 = no penetration within test time.

Not sure which glove you need?